NETMAP with SCALANCE M-800
SCALANCE M-800 Getting Started
Getting Started, 06/2015, C79000-G8976-C337-04
205
Settings used
For the configuration example, the devices are given the following IP address settings:
Name
Interface
IP address
Station
IP subnet 1
M876 LAN interface
P1
(vlan1)
192.168.20.1
255.255.255.0
WAN interface
(ppp0)
Dynamic IP address from the provider
The device is, however, reachable via a dynamic
DNS service, e.g. example.no-ip.com
PC1 LAN interface 192.168.20.20
255.255.255.0
Master station
IP subnet 2
M816
LAN interface
P1
(vlan1)
192.168.10.1
255.255.255.0
WAN interface
(ppp0)
Fixed IP address (WAN IP address), e.g.
91.19.6.84
PC2 Ethernet
(LAN 2)
192.168.10.10
255.255.255.0
Examples
There are the following examples of NETMAP
1. NETMAP for the local network (Page 206)
2. NETMAP for the remote network (Page 211)
3. NETMAP for the local and remote network (Page 216)