Configuring with Web Based Management 
  6.3 "Wizard" menu 
SCALANCE W780/W740 to IEEE 802.11n Web Based Management 
Configuration Manual, 08/2018, C79000-G8976-C267-13 
107 
● 
 
Specify how the MAC address is assigned to the client. The following are possible: 
–  Automatic 
The client automatically adopts the source MAC address of the first frame that it 
receives over the Ethernet interface. 
–  Manual 
If you select "Manual", enter the MAC address in the "MAC Address" column. 
–  Own 
–  The client uses the MAC address of the Ethernet interface for the WLAN interface. 
–  Layer 2 Tunnel 
The client uses the MAC address of the Ethernet interface for the WLAN interface. 
The network is also informed of the MAC addresses connected to the Ethernet 
interface of the client. Up to eight MAC addresses can be used. 
● 
 
Enter the MAC address of the client. The input box can only be edited if you have set 
"Manual" for the "MAC Mode". 
● 
 
–  Enabled 
In client mode, the device attempts to connect to the network with the best 
transmission quality and that has suitable security settings. 
–  Disabled 
The client attempts to connect to the network from the SSID list that has the best 
transmission quality. 
Table 2 contains the following columns: 
● 
 
Shows the available WLAN interfaces. 
● 
 
Enter the SSID of the access point with which the client connects. In the Basic Wizard, 
you can only specify one SSID. After completing the Basic Wizard, you can define further 
SSIDs with "Interfaces > WLAN > Client". 
● 
 
Shows the assigned security context. In the Basic Wizard only one security context is 
available. After completing the Basic Wizard, you can create and configure further 
security contexts in "Security > WLAN > Basic".