Configuring with Web Based Management   
6.5 "System" menu 
  SCALANCE W780/W740 to IEEE 802.11n Web Based Management 
260  Configuration Manual, 08/2018, C79000-G8976-C267-13 
The table has the following rows: 
● 
 
Shows the status of the C-PLUG. The following are possible: 
–  ACCEPTED 
There is a C-PLUG with a valid and suitable configuration in the device. 
–  NOT ACCEPTED 
Invalid or incompatible configuration on the inserted C-PLUG. 
–  NOT PRESENT 
No C-PLUG is inserted in the device. 
–  FACTORY 
C-PLUG is inserted and does not contain a configuration. This status is also displayed 
when the C-PLUG was formatted during operation. 
–  MISSING 
No C-PLUG is inserted. Functions are configured on the device for which a license is 
required. 
● 
 
Shows the SIMATIC NET product line that used the C-PLUG or KEY-PLUG previously. 
● 
 
Shows the device type within the product line that used the C-PLUG or KEY-PLUG 
previously. 
● 
 
The version of the configuration structure. This information relates to the configuration 
options supported by the device and has nothing to do with the concrete hardware 
configuration. This revision information does not therefore change if you add or remove 
additional components (modules or extenders), it can, however, change if you update the 
firmware.