Configuring with Web Based Management   
6.10 "iFeatures" menu 
  SCALANCE W780/W740 to IEEE 802.11n Web Based Management 
414  Configuration Manual, 08/2018, C79000-G8976-C267-13 
The page contains the following boxes: 
● 
 
Enable or disable the iPCF-MC mode of the SCALANCE W700 device. 
For PROFINET communication, we recommend enabling the iPCF-MC mode. By 
enabling iPCF-MC, the data rates provided by the access point are adapted.  
We strongly recommend that you retain the default setting for the data rates (802.11 a/b/g 
= 6, 9 and 12 Mbps and 802.11n = MCS 2). 
● 
 
These settings determine which device generation can establish a connection to this 
device. 
–  Enabled 
Only the devices that communicate with the IEEE 802.11n standard and have the 
"Legacy Free (iPCF-MC-LF)" setting enabled are accepted. WLAN mode 
IEEE 802.11n need not be enabled for this, however.  
This setting prevents performance from being slowed down by the IEEE 802.11 a/b/g 
device generation.  
–  Disabled 
All device generations (IEEE 802.11 a/b/g/n) are accepted. 
● 
(only in access point mode) 
Select the update time configured for the network to which the access point is connected. 
The lowest value for the update time is 32 ms. 
● 
 (only in access point mode) 
Specify which protocol is handled with priority. 
–  PROFINET 
if you set PROFINET, there must be no PROFINET controller downstream from the 
client. 
–  EtherNet/IP 
If you set Ethernet/IP, there must be no scanner downstream from the client.