EasyManua.ls Logo

Siemens SCALANCE X-300 Series - Page 54

Siemens SCALANCE X-300 Series
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
6.2 Connectors and electrical data
SCALANCE X-300
54 Compact Operating Instructions, 05/2016, A5E00982643-14
Table 6- 5 Electrical data: Power supply
Rated voltage
Safety extra-low voltage (SELV)
Voltage range
Permitted voltage range
including total ripple
24 VDC
19.2 VDC - 28.8 VDC
18 VDC - 32 VDC
Table 6- 6 Electrical data: Power consumption
Device variant
Power loss
at 24 VDC
Current consumption at
rated voltage 24 VDC
Overcurrent protection
at input (non-
replaceable fuse)
X304-2FE
6.2 W
260 mA
3 A / 32 V
X306-1LD FE
4.8 W
200 mA
3 A / 32 V
X307-3,
X307-3LD,
X308-2,
X308-2LD,
X308-2LH,
X308-2LH+,
X310,
X310FE,
X320-1 FE
9.6 W 400 mA 3 A / 32 V
X320-3LD FE
12 W
500 mA
3 A / 32 V
Table 6- 7 Electrical data: Signaling contact
Voltage via signaling contact
24 VDC
Switching capacity (resistive load)
max. 100 mA
Table 6- 8 Plug-in terminal block for connectors of the power supply and signaling contact
Power supply
1 x 4-pin
Signaling contact
1 x 2-pin
Table 6- 9 Electrical data: Transmitter output (optical) and receiver input
Device variant
Transmitter output (optical)
Receiver input
min. [dBm]
max. [dBm]
Sensitivity min. [dBm]
Input power max.
[dBm]
X304-2FE
-19
-14
-32
-3
X306-1LD FE
-15
-8
-34
-3

Table of Contents