EasyManua.ls Logo

Siemens SIMATIC 6DL1131-6DF00-0PK0 - Terminal Assignment of the DI 8×24

Siemens SIMATIC 6DL1131-6DF00-0PK0
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description
The pin assignment is made as follows:
Table 5-1 Terminal assignment of the DI 8×24...125VDC HA
Terminal Assignment Terminal Assignment Explanations
1 DI
0
2 DI
1
DI
n
: Input signal, channel n
2M: Signal voltage
1P1: Supply voltage L+ of the voltage bus 1P
2P1: Supply voltage L+ of the voltage bus 2P
1P2: Ground reference of the voltage bus 1P
2P2: Ground reference of the voltage bus 2P
7
DI.6+
8
1
DI.0+
2
3
DI.2+
4
5
DI.4+
6
1P1
L+
24VDC
M
1P2
2P1
L+
24VDC
M
2P2
MAX. 10 A
DI.7+
DI.1+
DI.3+
DI.5+
DI
15
16
9
10
11
12
13
14
2M
3 DI
2
4 DI
3
5 DI
4
6 DI
5
7 DI
6
8 DI
7
9 2M 10 2M
11 2M 12 2M
13 2M 14 2M
15 2M 16 2M
1P1 L+ 1P2 M
2P1 L+ 2P2 M
Notice
Note di󹪜erences in potential
The load voltage supply and the signal voltage of the I/O module are electrically isolated.
The connection of the load supply voltage and the signal voltage is only permissible when no compensating currents are
󹪞owing as a result of a di󹪜erence in potential.
The connection of additional, external devices to terminals with the assignment 2M is not permissible. The additional load
may result in the destruction of the I/O module as well as further faults.
Terminal
5.1 Terminal assignment
DI 8x24...125VDC HA
16 Equipment Manual, 10/2021, A5E39288633-AD

Other manuals for Siemens SIMATIC 6DL1131-6DF00-0PK0

Related product manuals