Protection
7.2 Configuring access protection for the CPU
CPU 1516pro-2 PN (6ES7516-2PN00-0AB0)
60 Operating Instructions, 11/2019, A5E35873416-AC
7.2 Configuring access protection for the CPU
Introduction
The CPU offers four different access levels to limit access to specific functions.
By setting up the access levels and the passwords for a CPU, you limit the functions and
memory areas that are accessible without entering a password. The individual access levels
as well as their associated passwords are specified in the object properties of the CPU.
Rules for passwords
Ensure that passwords are sufficiently secure. Passwords must not follow a machine-
recognizable pattern. Apply the following rules:
Assign a password that is at least 8 characters long.
Use different cases and characters: uppercase/lowercase, numbers and special
characters.
Access levels of the CPU
Table 7- 1 Access levels and access restrictions
Access levels
Access restrictions
Complete ac-
cess (no protec-
tion)
Every user can read and change the hardware configuration and the blocks.
Read access With this access level, read-only access to the hardware configuration and the
blocks is possible without entering a password, which means you can download
hardware configuration and blocks to the programming device. In addition, HMI
access and access to diagnostics data is possible.
It is not possible to download either blocks or the hardware configuration to the
CPUs without the password.
Additionally, the following are
not
possible without the password: Writing test func-
tions and firmware update (online).
HMI access With this access level only HMI access and access to diagnostics data is possible
without entering the password.
Without entering the password, you can neither load blocks and hardware configu-
ration into the CPU, nor load blocks and hardware configuration from the CPU into
the programming device.
Additionally, the following are
not
possible without the password: Test functions,
changing the operating mode (RUN/STOP), firmware update and display of
online/offline comparison status.
No access
(complete pro-
tection)
When the CPU has complete protection, no read or write access to the hardware
configuration and the blocks is possible (without access authorization in the form
of a password). HMI access is also not possible. The server function for PUT/GET
communication is disabled in this access level (cannot be changed).
Authentication with the password will again provide you full access to the CPU.
An enumeration of which functions are available in the different access levels is available in
the "Setting options for the protection" entry in the STEP 7 online help.