Technical specifications
8.7 Active Management Technology (AMT)
SIMATIC IPC547G
Operating Instructions, 04/2020, A5E49948632-AA
167
8.7.3 Activate AMT
For security reasons, AMT is not enabled on new devices.
Procedure
1. Connect the AMT PC by means of "Create Internet connection" when using the
corresponding LAN controller (LAN 1).
2. If necessary, first reset AMT to the default status.
You can find the required information in the section "Reset AMT with Unconfigure ME
(Page 168)".
3. To access the BIOS, press the <F2> key while the device is booting.
4. Select the "Intel AMT" parameter in the "Advanced > AMT Configuration" menu.
5. Exit BIOS with the key <F4> "Save & Exit".
The AMT PC starts.
6. To access the MEBx, press the <Ctrl+P> keyboard shortcut at system power-up.
7. In the login dialog, enter the standard password "admin".
8. Change the default password.
The new password must include the following characters:
In total at least eight characters
One upper case letter
One lower case letter
One number
A special character . ! @ # $ % ^ & *
Note
The underscore and blank
space are valid password characters but do not increase
password complexity.
9. Enable "Intel (R) AMT Configuration > Manageability Feature Selection".
10.Enable "Intel (R) AMT Configuration > Activate Network Access".