28 Operating Instructions, 02/2017, C70000-G8976-C218-08
With this power supply (6 to 9 VDC), the CP 1616 can operate as a switch even if the PC is
turned off.
NOTICE
UL approval
These modules are intended for installation in Siemens PCs which are approved in
accordance with UL 508 and listed under UL file number E85972. These PCs must comply
with the UL 508 guidelines on "limited voltage / current" or have an "LPS supply" in
accordance with UL 60950 or a "Class 2 supply" in accordance with UL 1310/UL 1885.
2.2.2
Procedure for installing the CP 1616
WARNING
Do not put any damaged parts into operation!
Do not use any parts that show evidence of damage!
Recommendation for installation when using Linux
Install the CP 1616 first and then install the CP 1616 driver.
Requirements and conditions
If available, enable the plug-and-play mechanism in the BIOS of your computer.
The CP 1616 communications processor requires a PCI slot with master capability.
Note
Note on the number of possible CP 1616s in one computer
A maximum of one CP 1616 module can be installed in one PG/PC.
Installation and connection of the CP 1616
To install and connect up the CP 1616 follow the steps outlined below:
1. Turn off your computer and pull out the power cable connector from the socket.
2. Open the computer housing as described in the manual accompanying your PG/PC.
3. Remove the cover of a free PCI slot in your computer.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET CP 1604 and is the answer not in the manual?

Siemens SIMATIC NET CP 1604 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET CP 1604
CategoryController
LanguageEnglish

Related product manuals