Application and functions
1.3 Requirements for use
CP 443-5 Extended
Equipment Manual, 01/2023, C79000-G8976-C162-10
11
S7 communication and PG/OP communication
PG functions with uploading / downloading of FM modules, configuration / diagnostics
and routing
Note on routing: Dynamic switchover to alternative paths (for example if there is a
problem on one of the possible transmission paths) is not supported.
Operator control and monitoring functions (HMI)
Download S7 connections and gateways in RUN.
Client and server for data exchange on S7 connections using communications function
blocks (faulttolerant S7 connections also possible)
Timeofday synchronization via PROFIBUS
The CP forwards timeofday synchronization frames from the LAN to the station (CPU =
time slave) or from the station to the LAN (CPU= time master).
Another option is for this station to be synchronized via a different LAN. The timeofday
synchronization frame must be forwarded over PROFIBUS for the synchronization of
further stations.
The CP supports time stamping of distributed process signals in conjunction with the
IM 153.
Timeofday status value (standard/daylight saving time switchover, synchronization
status).
Data record routing
You can use the CP as a router for data records intended for field devices (for example DP
slaves). SIMATIC PDM (Process Device Manager) is a tool that creates data records of this
type for assigning parameters to field devices.
The services of the CP 4435 Extended module listed above can be used independently at the
same time.
Replacing a module without a programming device
When installing the CP 4435 Extended, the configuration data of the CP is always stored in
the CPU. This means that replacing modules is possible without having to download the
configuration data from the PG.
Storage of the configuration data is protected from power failure by the battery backup or
the flash memory card in the CPU.
See also section Converting older systems (Page 14).
1.3 Requirements for use
The CP 4435 Extended described here is supported by all CPU operating systems in the
versions listed in Tables 2-1 and 2-2 below.

Other manuals for Siemens SIMATIC NET S7-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET S7-400 and is the answer not in the manual?

Siemens SIMATIC NET S7-400 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET S7-400
CategoryConference System
LanguageEnglish

Related product manuals