Application and functions
1.3 Requirements for use
CP 443-5 Extended
Equipment Manual, 01/2023, C79000-G8976-C162-10
15
CPU Article number Version Number of AG_SEND or
AG_RECV calls at same
time
SYNC / FREEZE
6ES7 414-1XG02-0AB0
2 or higher
12 / 12
+
CPU 414-2
128 KB
6ES7 414-2XG01-0AB0
2 or higher
12 / 12
-
6ES7 414-2XG02-0AB0
2 or higher
12 / 12
+
CPU 414-2
384 KB
6ES7 414-2XJ00-0AB0
4 or higher
12 / 12
-
6ES7 414-2XJ01-0AB0
2 or higher
12 / 12
+
CPU 416-1
6ES7 416-1XJ01-0AB0
2 or higher
32 / 32
-
6ES7 416-1XJ02-0AB0
1 or higher
32 / 32
+
CPU 416-2
0.8 MB
6ES7 416-2XK00-0AB0
4 or higher
32 / 32
-
6ES7 416-2XK01-0AB0
1 or higher
32 / 32
+
CPU 416-2
1.6 MB
6ES7 416-2XL00-0AB0
4 or higher
32 / 32
-
6ES7 416-2XL01-0AB0
1 or higher
32 / 32
+
Legend:
+ => The characteristic is supported / the listed mode is possible
- The characteristic is not supported / the listed mode is not possible
Table 1- 3 Use with no longer available CPU types - part 2
CPU Article number of
the CPU:
6ES7...
Firmware
version
Number of
AG_SEND or
AG_RECV calls at
same time
a = SYNC/FREEZE functionality
b = DP-V1 functionality
c = CiR / HCiR functionality
1)
d = enable / disable DP slaves
e = identify bus topology
a
b
c
d
e
CPU 412
..412-1XF03-0AB0
as of V3.1
24 / 24
+
+
+
+
-
CPU 412-2
..412-2XG00-0AB0
as of V3.1
24 / 24
+
+
+
+
-
CPU 414-2
..414-2XG03-0AB0
as of V3.1
24 / 24
+
+
+
+
-
CPU 414-3
..414-3XJ00-0AB0
as of V3.1
24 / 24
+
+
+
+
-
CPU 414-4H
..414-4HJ00-0AB0
as of V3.1
24 / 24
-
+
+
-
-
CPU 416-2
..416-2XK02-0AB0
as of V3.1
64 / 64
+
+
+
+
-
CPU 416-3
..416-3XL00-0AB0
as of V3.1
64 / 64
+
+
+
+
-
CPU 416F-2
..416-2FK02-0AB0
as of V4.0
64 / 64
+
+
+
+
-
CPU 417-4
..417-4XL00-0AB0
as of V3.1
64 / 64
+
+
+
+
-
CPU 417-4H
..417-4HL00-0AB0
as of V2.1
64 / 64
-
-
+
-
-
..417-4HL01-0AB0
as of V3.1
64 / 64
-
+
+
-
-
Legend:
+ => The characteristic is supported / the listed mode is possible
- => The characteristic is not supported / the listed mode is not possible
1) All CPUs are capable of CiR (the H-CPUs HCiR).

Other manuals for Siemens SIMATIC NET S7-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET S7-400 and is the answer not in the manual?

Siemens SIMATIC NET S7-400 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET S7-400
CategoryConference System
LanguageEnglish

Related product manuals