EasyManuals Logo

Siemens SIMATIC NET SCALANCE S615 User Manual

Siemens SIMATIC NET SCALANCE S615
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background image
Security recommendations
SCALANCE S615
Operating Instructions, 10/2022, C79000-G8976-C389-07
17
Check whether use of the following protocols is necessary:
Telnet
HTTP
Broadcast pings
Non authenticated and unencrypted interfaces
ICMP (redirect)
LLDP
DHCP Options 66/67
SNTP
NTP
TFTP
TIA Portal Cloud Connector (not available with SCALANCE MUM85x)
VRRPv3
DNS
SNMPv1/V2c
If a secure alternative is available for a protocol, use it.
The following protocols provide secure alternatives:
SNMPv1/v2 → SNMPv3
Check whether use of SNMPv1 is necessary. SNMPv1 is classified as non-secure. Use
the option of preventing write access. The product provides you with suitable setting
options.
If SNMP is enabled, change the community names. If no unrestricted access is
necessary, restrict access with SNMP.
HTTP → HTTPS
Telnet → SSH
NTP → Secure NTP
TFTP → SFTP
TIA Portal Cloud Connector using a secure connection. Use the "TIA Portal Cloud
Connector" integrated in the product over a VPN solution (e.g. SINEMA RC).
Configure the firewall settings of the SCALANCE M800/S615 (e.g. predefined IPv4 rules
"Cloud Connector" to prevent unauthorized access of network devices to the "TIA Portal
Cloud Connector Server").
Using a firewall, restrict the services and protocols available to the outside to a minimum.
For the DCP function, enable the "Read Only" mode after commissioning.

Other manuals for Siemens SIMATIC NET SCALANCE S615

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE S615 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE S615 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE S615
CategoryNetwork Router
LanguageEnglish

Related product manuals