6. Connect the device to the local network, refer to the section "Ethernet port (Page53)".
7. Connect the terminal with as short a cable as possible 150 mm and a large cross-sectional
area of 1.5 mm² to the functional ground of the system, see section "Terminals (Page 23)" and
section "Grounding (Page50)".
Dismantling
1. Disconnect all connected cables.
2. Loosen the attachment of the mounting frame.
3. Using a screwdriver, pull down the catch on the rear of the device.
4. Push the device out of the mounting frame.
4.8 Mounting on a pedestal
Installation
1. Place the third housing guide of the device on the top edge of the pedestal .
2. Press the device down against the pedestal until the spring catch locks in place .
3. Connect the power supply, refer to the section "Power supply (Page49)".
Installation and removal