4.5 Installing on the S7-300 standard rail
Installation
1. Place the second housing guide of the device on the top edge of the standard rail .
2. Press the device down against the standard rail until the spring catch locks in place .
3. Connect the power supply, refer to the section "Power supply (Page49)".
4. Fit the connectors for the digital input and digital output, refer to the section "Digital input/
output (Page51)".
5. Connect the device to the local network, refer to the section "Ethernet port (Page53)".
6. Connect the terminal with as short a cable as possible 150 mm and a large cross-sectional
area of 1.5 mm² to the functional ground of the system, see section "Terminals (Page 23)“ and
section “Grounding (Page50)“.
Dismantling
1. Disconnect all connected cables.
2. Using a screwdriver, pull down the catch on the rear of the device.
3. Remove the device from the standard rail.
Installation and removal
4.5Installing on the S7-300 standard rail
SCALANCE S615
Operating Instructions, 05/2023, C79000-G8976-C389-08 37