Modules
4.2Available Modules
Ports: 4
Port Type: LC
Distance: 10 km (6.2
mi)
Power Consumption: 5
W
RUGGEDCOM RX1500PN LM FG50 Specifications
SFP Sockets: 2
Speed: 1000 Mbps
Power Consumption: 7
W
Article Numbers
6GK6015-0AL20-0JB0
(Standard)
6GK6015-0AL20-0JB1
(Conformal Coated)
RUGGEDCOM RX1500PN LM FG51 Specifications
Mode: MM
Speed: 1000 Mbps
Interface: SX
Wavelength: 820 nm
Ports: 2
Port Type: LC
Distance: 500 m (1640
ft)
Power Consumption: 5
W
Article Numbers
GK60150-AL200-DC0
(Standard)
GK60150-AL200-DC1
(Conformal Coated)
RUGGEDCOM RX1500PN LM FX50 Specifications
SFP Sockets: 4
Speed: 100 Mbps
Power Consumption: 5
W
Article Numbers
6GK6015-0AL20-0JC0
(Standard)
6GK6015-0AL20-0JC1
(Conformal Coated)
RUGGEDCOM RX1500PN LM FX51 Specifications
Mode: SM
Speed: 100 Mbps
Interface: FX
Wavelength: 1310 nm
Ports: 2
Port Type: LC
Distance: 2 km (1.2 mi)
Power Consumption: 5
W
Article Numbers
6GK6015-0AL20-0BJ0
(Standard)
6GK6015-0AL20-0BJ1
(Conformal Coated)
RUGGEDCOM RX1500PN LM 6FX50 Specifications
SFP Sockets: 6
Speed: 100 Mbps
Power Consumption: 7
W
Article Numbers
6GK6015-0AL20-0JD0
(Standard)
6GK6015-0AL20-0JD1
(Conformal Coated)
RUGGEDCOM RX1500PN LM 6FX51 Specifications
Mode: MM
Speed: 100 Mbps
Article Numbers
6GK6015-0AL20-0BK0
(Standard)
RUGGEDCOM RX1511
Installation Manual, 04/2021, C79000-G8976-1056-20
31

Other manuals for Siemens SIMATIC NET