Technical Specifications
5.3Operating Environment
5.3 Operating Environment
The RUGGEDCOM RX1511 is rated to operate under the following environmental
conditions.
Note
Temperature limits for select line modules may differ from that which can be
withstood by the RUGGEDCOM RX1511. Make sure the selected modules are
rated for the expected environmental conditions before deployment. For more
information, refer to the RUGGEDCOM RX1511 Series Modules Catalog.
Ambient Operating
Temperature
ab
-40 to 85 °C (-40 to 185 °F)
Ambient Storage Temperature -40 to 85 °C (-40 to 185 °F)
Ambient Relative Humidity
c
5% to 95%
Maximum Altitude 2000 m (6562 ft)
a
Measured from a 30 cm (12 in) radius surrounding the center of the enclosure.
b
Operating temperature may vary based on the limitations of installed SFPs. Refer to the RUGGEDCOM
SFP Transceivers Catalog for SFP temperature ratings.
c
Non-condensing.
5.4 Mechanical Specifications
Weight Approximately 3.2 kg (7 lb)
Ingress Protection IP30
Enclosure Aluminum
5.5 Dimension Drawings
Note
All dimensions are in millimeters, unless otherwise stated.
46
RUGGEDCOM RX1511
Installation Manual, 04/2021, C79000-G8976-1056-20

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals