Control interface parameters
OUTPUT_VALUE
The interpretation of the value OUTPUT_VALUE depends on the set operating mode.
OUTPUT_VALUE is always updated. When an invalid value is detected (outside the
permissible range), the error memory bit ERR_OUT_VAL is set until a valid value is
detected. During the error condition the invalid value is ignored and the PWM channel
continues with the last valid OUTPUT_VALUE. Note that, in the frequency output mode, it is
also possible that no last valid value is available. In this case the pulse output returns the
value 0, i.e. there is no pulse output.
Please note that the on-load factor is not checked in PWM mode. If the on-load factor is
greater than the format permits, the PWM channel uses a ratio of 100 %. 0 % in effect for
values < 0.
SLOT, MODE_SLOT and LD_SLOT
Use these control interface fields if you occasionally change the period duration in PWM
mode before the start of the output sequence or during operation. You can find a description
of the interaction between SLOT, MODE_SLOT and LD_SLOT under Handling the SLOT
parameter (control interface) (Page 64)
SW_ENABLE
If 0 1, activate the output sequence.
TM_CTRL_DQ
If 1, the output is controlled by the PWM channel and generates the pulse sequences
If 0, the output is controlled directly by the program using the SET_DQA assignments
SET_DQA
If 1, set the output A to 1, if TM_CTRL_DQ is inactive
If 0, set the output A to 0, if TM_CTRL_DQ is inactive
RES_ERROR
Resetting the error bit memory ERR_LD in the feedback interface

Table of Contents

Other manuals for Siemens SIMATIC S7-1500T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-1500T and is the answer not in the manual?

Siemens SIMATIC S7-1500T Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC S7-1500T
CategoryController
LanguageEnglish

Related product manuals