Latching
2.6 Making a Set/Reset network
Getting Started - Advanced
20 Training Documents, 09/2007, A5E01469795B
2.6 Making a Set/Reset network
To make sure you are using the least number of keystrokes and mouse clicks to create the
LAD networks, do the following:
1. Select the menu command Tools > Options
2. Select the Program Editor tab
3. Verify the "Enable operand editing after placing instruction" checkbox is checked
(enabled).
,
,
4
6
4
5
1HWZRUN
You have already learned how to
enter the Normally Open contacts
I0.0 and I0.1.
1. After marking the desired LAD
field, select the Bit Logic folder
with a single mouse click from the
list for operation families.
2. Then double click "Set" (or
"Reset") from the list of Bit Logic
operations.
3. In the already selected address
field, enter the output address
you want, Q0.0 in this case.
4. Select the lower bit field and
enter the number of bits to set
starting from address Q0.0
,
6
4
6
4