Expert Functions
5.6 Measuring Function
Connection of the SINAMICS S120 to the Technology CPU
Product Information, 09/2011, A5E00480378-04
163
Transferring the configuration to the Technology CPU
The Technology CPU configuration has been changed as a result of inserting the
TM17 terminal module and aligning with HW Config.
To transfer the modified configuration to the Technology CPU, follow these steps:
1. Open HW Config.
2. Perform a download.
3. To check the Drive CLiQ connection, switch to the S120_CU320 > Topology
folder in the S7T Config project navigator.
4. Compare the Drive CLiQ connection of the parameter assignment with your configuration
and adjust the topology or configuration as appropriate.