Cycle and Response Times of the S7-400
9.11 CBA response times
S7-400 Automation System, CPU Specifications
Manual, 10/2006, 6ES7498-8AA04-8BA0
9-29
General Information about Achievable CBA Response Times
The CBA response time increases if the CPU is performing additional tasks, such as
programmed block communication or S7 connections.
If you frequently call SFCs "PN_IN", "PN_OUT" or "PN_DP", you increase the CBA
processing times and therefore increase CBA response time.
A very small OB1 cycle increases the CBA response time when the PN interface is
updated automatically (at the cycle control point).