SINUMERIK 840C / SIMODRIVE 611D (DA)
104009 File cannot be loaded into NCK OK softkey
With SK Save and Load in NCK
Operation is aborted
An error has occurred while loading the file into the NCK.
Possible causes: File type cannot be loaded into NCK;
incorrect keyswitch position;
no communication with NCK.
Alarm in SW 5 and higher
105000 MMC power up
Power up
None
Time of MMC power is up noted in log
No error
105001 Too many messages
On setting alarms/messages
New alarm occurrences are not indicated until further alarms are acknowledged.
There are too many unacknowledged alarms/messages and a new alarm/message needs to be issued.
Cancel alarms/messages (Power on) or increase the number of alarms in the file alarm.ini
[Alarm]
Entries= <no. of alarms>, value < increase number of alarms
If the file alarm.ini does not exist or if no value is entered, the default for <no. of alarms> is 500.
Alarm from SW 6.3
105002 No communication to NCK!
Power up
MMC power up without NCK
A more detailed error diagnostic is entered in the log with alarm 105011. Wrong MD, e.g. too short IPO cycles,
control overloaded because of incorrect parameterization.
Check NCK driver, POWER ON
105003 NCK failed with error ...
Power up
Alarm 105005 is also output ––> see alarm 105005
[EPROM_ERROR]: EPROM error
[DRAM_ERROR]: DRAM error detected during power up
[DRAM_PROG_ERROR]: DRAM system program error
POWER ON, replace NCK hardware if necessary
105004 NCK reset please wait ...
Power up, with inch/metric switchover.
System can temporarily not be operated
NCK power up in progress, if a Power On is required for inch/metric switchover, this message is output.
Wait until NCK reset is completed and message disappears
Alarm from SW 6.3
105005 Please initiate NCK reset
Power up
S NCK cannot be operated
S Interlocking of NC START
MMC crash and subsequent power up does not cause the operating program to be interrupted. For safety
reasons an NCK RESET must be initiated at a suitable time.
An NCK system error has occurred. For more detailed diagnosis refer to messages 105003 or 105020.
Initiate NCK RESET
Scan
Effect
Explanation
Note
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Note
Note
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
1 Alarms
1.5.1 Alarm description
09/01

Table of Contents

Other manuals for Siemens SIMODRIVE 611-D

Related product manuals