04/96
Siemens AG 2001 All rights reserved 6FC5198jAB40
1–107
SINUMERIK 840C / SIMODRIVE 611D (DA)
105049 Operator panel interface ... faulty
After Power On
An interface which does not exist has been set in the config file of the master control
Siemens settings apply
Set correct interface and Power On
105050 Keyword unknown in line ... (master control)
After Power On
An unknown keyword is in the config file of the master control
Line is ignored
Correct and Power On
105051 Wrong value in ... line (master control)
After Power On
An incorrect value stands behind the keyword in the config file of the master control
Interpreted as value 0
Correct and Power On
105052 Text too long in line ... (master control)
After Power On
A string is too long in the config file of the master control
Line is ignored
Correct and Power On
105053 Missing value in line ... (master control)
After Power On
The value behind the keyword is missing in the config file of the master control
Line is ignored
Correct and Power On
105054 Too many masks in line ... (master control)
After Power On
There are too many masks for registering the alarms to be entered in the log in the config file of the master control
Line is ignored
Reduce number of masks and Power On
105055 Log ... created new OK softkey
Power up
Old entries have been deleted.
The existing log (alarm log = 1, service log = 2) could no longer be accessed.
Applies as from SW 4
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Note
1 Alarms
1.5.1 Alarm description