04/96
Siemens AG 2001 All rights reserved 6FC5198–jAB40
1–108
SINUMERIK 840C / SIMODRIVE 611–D (DA)
105056 Log ... cannot be created OK softkey
Power up
Power up without log
It was not possible to create a log file (alarm log = 1, service log = 2) (disk defective or full).
Check disk
Applies as from SW 4
105057 CAUTION: Virus alarm!!!
On powering up control after SysLock triggered a virus alarm
None
If the program SysLock finds that the size of the main memory has changed since its first initialization, a virus
alarm is triggered.
If this virus alarm is triggered, the system has to be examined and decontaminated with a virus scanner. In order to
allow the virus scanner to work properly, it is essential that the system is started up with a boot disk that is not
infected with a virus.
Alarm from SW 6.3
106000 Listing texts ... cannot be read
MMC power up
Listing texts cannot be used.
An essential system file cannot be read.
Notify service.
Applies as from SW 4
106001 Listing ... being prepared
Selection of a listing
The selected listing is prepared just once.
This text simply provides information and is intended to explain a delay that might occur. When selecting the same
listing again, this does not have to be prepared again.
Wait until the message disappears again.
Applies as from SW 4
106002 ... is being read
File functions MDD
A data block is being read in from harddisk.
This text simply provides information and is intended to explain a delay that might occur.
Wait until the message disappears again.
Applies as from SW 4
106003 ...: Error in data block ...
File functions MDD
A data block has not been completely read in.
A data block read in from harddisk (so-called punched tape format) contains an error.
Correct the error as far as possible and repeat the process.
Applies as from SW 4
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
1 Alarms
1.5.1 Alarm description
01/99