04/96
Siemens AG 2001 All rights reserved 6FC5198–jAB40
1–122
SINUMERIK 840C / SIMODRIVE 611–D (DA)
110118 Storage of ... not allowed here OK softkey
Save NC / NC source / start
No data transmission
Parameter ... stands for NC name
Part programs MFP/SPF can only be stored in a workpiece and GIA data can only be stored under NC data.
Position on/in a workpiece or in the case of GIA data to NC data using the data selector.
110119 Data not transferred or incompletely OK softkey
Computer link / save start
Computer link / load start / OK
Not all data transfers, the last file may be incomplete
Cause perhaps in error log
Rectify cause, restart transmission
110120 Data cannot be read in OK softkey
DATA INPUT START
File has neither been read in the clipboard nor under the target path.
Cause (e.g. no write authorization, file opened by ASCII editor) can be seen in the error log
Eliminate cause. Restart data input.
Applies as from SW 4.4
110121 Option not available OK softkey
On computer link
–
Computer link module not slotted in or not active
Activate computer link module (CP)
110122 NCK password not set OK softkey
When loading NCK data
The selected data are not loaded
Password required for loading GIA data
Set password in diagnosis
110123 Conversion error in workpiece <%1>
During programming when softkey ”Start converter” is pressed or if a workpiece is to be loaded from NCK.
Faulty part program MPF (SFFs as well if applicable) is (are) created.
Displays the name of the workpiece (<%1) with which the conversion error occurred.
Eliminate the logged error in the relevant EPF and restart the converter.
Alarm from SW 6.3
110124 Conversion warning in workpiece <%1>
Same as 110123 except a program error is evaluated as a warning.
Alarm from SW 6.3
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Note
Note
1 Alarms
1.5.1 Alarm description
01/99