Warning
The successful and safe operation of this equipment and motors is dependent on professional
transport, storage, installation and mounting as well as careful operator control, service and
maintenance.
For special versions of the drive units and motors, information and data in the catalogs and
quotations additionally apply.
In addition to the danger and warning information/instructions in the technical customer docu-
mentation supplied, the applicable domestic, local and plant-specific regulations and require-
ments must be carefully taken into account.
Caution
The motors can have surface temperatures of over +100 °C.
This is the reason that temperature-sensitive components, e.g. cables or electronic compo-
nents may neither be in contact nor be attached to the motor.
When connecting up cables, please observe that they
– are not damaged
– are not subject to tensile stress
– cannot be touched by rotating components.
Caution
Motors should be connected up according to the circuit diagram provided. They must not be
connected directly to the three-phase supply because this will damage them.
SIMODRIVE and SIMOVERT MASTERDRIVES drive units with AC motors are subject, as
part of the type test, to a voltage test corresponding to EN 50178. According to EN 60204-1,
Section 19.4, while electrical equipment of industrial machines are being subject to a voltage
test, all of the SIMODRIVE and SIMOVERT MASTERDRIVES drive unit connections must be
disconnected/withdrawn in order to avoid damaging the SIMODRIVE and SIMOVERT MAS-
TERDRIVES drive units.
Note
SIMODRIVE and SIMOVERT MASTERDRIVES drive units with motors fulfill, when opera-
tional and in dry equipment rooms, the Low-Voltage Directive 73/23/EEC.
SIMODRIVE and SIMOVERT MASTERDRIVES drive units with motors fulfill, in the configura-
tions specified in the associated EC Declaration of Conformity, EMC Directive 89/336/EEC.