Incoming Line and Suggested Transformer,(if required), Connections
611V3usa.PPT
Sheet 2/3 - 8/10/ 98
Section A Power & Grounding
Pri.
Sec.
Isolation Transformer
Output 400 or 480 VAC
to (sheet 1)
Auto-Former
Output 400 or 480 VAC
to (Sheet 1)
Auxiliary Contact:
Opens before Power
Contacts.
Incoming
Lines
See Detail 1
L1
L2
L3
Ground
Continue Ground to
I/R - U/E Module
(sheet 1)
5)
6)
Continue Ground to
U/E Module (sheet 1)
7)
For explanation of notes [ *) ], see sheet 3/3
8.1)
8)
8.2)
L1
L2
L3
PEN
Detail 1
TN-C Line Configuration
Wye connection with Neutral Ground
Ground