EasyManuals Logo

Siemens SIMODRIVE 611A User Manual

Siemens SIMODRIVE 611A
329 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #287 background imageLoading...
Page #287 background image
1FT5
08.95
1FT5/3-37
Siemens AG 1997 All Rights reserved 6SN1197–0AA20
SIMODRIVE 611 (PJ)
3.2.1 Standard motors
Cantilever force F
Q
at distance x from the shaft shoulder for a nominal bearing
lifetime of 20,000 hours.
2010 x[mm]
F
Q
0 23 30
n=2000 RPM
n=3000 RPM
n=4500 RPM
n=6000 RPM
n=8000 RPM
0
100
200
300
Permissible axial force as a function of the cantilever force.
N
F
Q
AS
100
200
300
0
0
100 200 N 300
F
A
AS
8000
n=2000 RPM
3000
6000
4500
Cantilever force
1FT5034 to
1FT5036
Axial force
1FT5034 to
1FT5036
1FT5 AC servomotors
3.2 Cantilever/axial force dia
g
rams