EasyManuals Logo

Siemens SIMODRIVE 611A User Manual

Siemens SIMODRIVE 611A
329 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #288 background imageLoading...
Page #288 background image
1FT5
08.95
1FT5/3-38
Siemens AG 1997 All Rights reserved 6SN1197–0AA20
SIMODRIVE 611 (PJ)
Cantilever force F
Q
at distance x from the shaft shoulder for a nominal bearing
lifetime of 20,000 hours.
100
200
300
2010 x[mm]
F
Q
400
030
500
600
n=2000 RPM
n=3000 RPM
n=4500 RPM
n=6000 RPM
n=8000 RPM
N
Permissible axial force as a function of the cantilever force.
N
F
Q
AS
400
500
100
200
300
0
0
100 200 300
F
A
AS
8000
n=2000 RPM
3000
6000
4500
400 500 N 600
Cantilever force
1FT5042 to
1FT5046
Axial force
1FT5042 to
1FT5046
1FT5 AC servomotors
3.2 Cantilever/axial force dia
g
rams

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMODRIVE 611A and is the answer not in the manual?

Siemens SIMODRIVE 611A Specifications

General IconGeneral
BrandSiemens
ModelSIMODRIVE 611A
CategoryInverter
LanguageEnglish

Related product manuals