SIMODRIVE 611A Installation and Start–Up Guide/IAA/–04.97 Edition
Table 1-6 Adaptation table for feed module 25/50 A
Servomotor
Current limit
1)
Current controller gain
1FT M[Nm] I[A] n
td
[RPM]
Contacts
I [A]
Contacts
Kp(I)1FT... M
o
[Nm] I
o
[A] n
rated
[RPM]
2 3 4 5
I
max
[A]
6 7 8 9
K(I)
5044–VAK71 1.3 2.3 6000 o o x x 13.0 x x o o 2.5
5046–VAF71
5046–VAK71
2.6
2.6
3.0
4.7
3000
6000
o
o
x
o
o
x
x
o
15.0
25.0
o
x
o
x
x
o
o
o
4.0
2.5
5062–VAG71
5062–VAK71
2.2
2.2
2.7
3.9
4000
6000
x
o
o
x
x
x
x
o
13.0
19.5
x
x
o
o
o
x
x
o
6.5
4.5
5064–VAC71
5064–VAF71
5064–VAG71
5064–VAK71
4.5
4.5
4.5
4.5
2.7
4.1
5.5
8.0
2000
3000
4000
6000
o
x
o
o
o
x
o
x
x
x
x
o
x
o
o
o
13.0
19.5
25.0
34.0
x
x
o
x
x
x
x
x
x
o
x
o
x
x
o
o
11.5
8.0
5.5
2.5
5066–VAC71
5066–VAF71
5066–VAG71
5066–VAK71
6.5
6.5
6.5
6.5
3.9
6.0
7.9
11.6
2000
3000
4000
6000
x
x
o
o
x
x
x
o
x
o
o
o
o
o
o
o
19.5
30.5
34.0
50.0
x
x
x
o
x
x
o
o
x
o
x
x
x
x
o
o
11.5
8.0
4.5
4.0
5070–VAF71
5070–VAG71
5070–VAK71
3.0
3.0
3.0
2.6
3.6
5.3
3000
4000
6000
o
x
o
x
o
o
x
o
x
x
x
o
12.0
17.0
25.0
x
o
x
x
o
o
x
x
o
x
x
x
11.5
9.5
6.5
5071–VAC71
5071–VAF71
5071–VAG71
5071–VAK71
4.5
4.5
4.5
4.5
2.9
4.3
5.2
7.9
2000
3000
4000
6000
o
o
o
o
o
x
o
x
x
x
x
o
x
o
o
o
13.0
20.5
25.0
34.0
x
o
x
o
x
o
x
o
x
x
o
x
x
x
x
o
11.5
9.5
8.0
4.0
5072–VAC71
5072–VAF71
5072–VAG71
5072–VAK71
10.0
10.0
10.0
10.0
6.1
9.1
12.0
17.5
2000
3000
4000
6000
o
x
o
o
o
o
o
o
x
o
o
o
o
o
o
o
25.0
42.5
50.0
50.0
x
o
x
x
x
o
o
x
x
x
o
o
x
x
x
o
11.5
9.5
6.5
2.5
5073–VAC71
5073–VAF71
5073–VAG71
5073–VAK71
7.0
7.0
7.0
7.0
4.3
6.4
8.1
12.5
2000
3000
4000
6000
o
x
x
o
x
x
o
o
x
o
o
o
o
o
o
o
20.5
30.5
42.5
50.0
x
x
o
x
x
x
x
x
x
o
o
o
x
x
x
o
11.5
8.0
7.5
2.5
5074–VAC71
5074–VAF71
5074–VAG71
5074–VAK71
14.0
14.0
14.0
14.0
8.5
13.0
16.5
25.0
2000
3000
4000
6000
x
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
42.5
50.0
50.0
50.0
x
x
x
x
x
o
o
o
x
o
x
o
x
x
o
o
11.5
6.5
4.5
1.0
5076–VAC71
5076–VAF71
5076–VAG71
18.0
18.0
18.0
11.5
16.5
21.5
2000
3000
4000
o
o
o
o
o
o
o
o
o
o
o
o
50.0
50.0
50.0
o
x
x
x
o
x
x
x
o
x
o
o
11.0
4.5
2.5
5100–VAC71
5100–VAF71
5100–VAG71
5100–VAK71
10.0
10.0
10.0
10.0
6.2
9.2
12.5
18.0
2000
3000
4000
6000
x
x
o
o
x
o
o
o
o
o
o
o
o
o
o
o
30.5
42.5
50.0
50.0
x
x
x
x
x
o
o
x
x
o
x
o
x
x
o
o
11.5
6.5
4.5
2.5
5101–VAC71
5101–VAF71
5101–VAG71
15.0
15.0
15.0
9.4
14.5
17.5
2000
3000
4000
x
o
o
o
o
o
o
o
o
o
o
o
42.5
50.0
50.0
o
x
x
o
o
x
x
x
o
x
o
o
9.5
4.5
2.5
5102–VAA71
5102–VAC71
5102–VAF71
27.0
27.0
27.0
9.9
16.5
25.0
1200
2000
3000
x
o
o
o
o
o
o
o
o
o
o
o
42.5
50.0
50.0
x
x
x
x
o
x
x
o
o
x
x
o
11.5
6.5
2.5
1)The specified value is the maximum permissible current of the particular power module – motor combination. It may be
necessary to reduce the specified value depending on the driven mechanical system.
Feed modules (VS)
04.971.2 Current controller settings
03.96