Commissioning
4.4 Setting up a STEP 7 project
Connecting the SIMODRIVE 611U to the Technology CPU
18 Product Information, 03/2008, A5E00272066-05
Click the New button in the Properties - PROFIBUS Interface DP(DRIVE) (S0/S3.1)
window to assign a network to the DP drive interface. The PROFIBUS configuration is set
in the displayed dialog. Select the Network Settings tab for this purpose.
Set "2" as the largest PROFIBUS address
Set a transmission rate of 12 Mbit/s on the bus and DP as profile.
Figure 4-6 PROFIBUS subnet properties
Click the Options button and activate the Activate equidistant bus cycle checkbox in the
Constant Bus Cycle Time tab.
Figure 4-7 Activate isochronous bus cycle