Converter data sheets and characteristics
4.1 Forced ventilation
Commissioning instructions for SIMOTICS M-1PH8 Premium Performance
28 Commissioning Manual, 10/2014, 610.40106.40
Additional parameterization
Booksize Combi with 300% overload
400 V
480 V
Motor type selection
p300
1
1
Line resistance
p352
0.12
0.12
Current controller adaptation, starting point
KP
p391 8 8
Current controller adaptation, starting point
KP adapted
p392 10 10
Current controller adaptation, P gain adapta-
tion
p393 60 60
Current limit
p640
60
60
Maximum rotation speed
p1082
24,000
24,000
Torque limit, upper/motoring
p1520
20
20
Torque limit, lower/regenerative
p1521
-20
-20
Power limit, motoring
p1530
18.8
21.2
Power limit, regenerative
p1531
-18.8
-21.2
Maximum field-generating current
p1603
0
0
Pulse frequency setpoint
p1800
4
4
Modulator configuration
p1810
&H800
&H800
Current controller P gain
p1715
3
3
Reference speed reference frequency
p2000
24,000
24,000
Reference current
p2002
60
60
Reference torque
p2003
20
20
Hysteresis speed n_act > n_max
p2162
480
480

Other manuals for Siemens SIMOTICS M-1PH8