Fundamental safety instructions for the SIMOTICS documentation
1.1 Fundamental safety instructions
Commissioning instructions for SIMOTICS M-1PH8 Premium Performance
Commissioning Manual, 10/2014, 610.40106.40
17
1.1.4
Residual risks during the operation of electric motors
The motors may be operated only when all protective equipment is used.
Motors may be handled only by qualified and instructed qualified personnel that knows and
observes all safety instructions for the motors that are explained in the associated technical
user documentation.
When assessing the machine's risk in accordance with the respective local regulations (e.g.,
EC Machinery Directive), the machine manufacturer must take into account the following
residual risks emanating from the control and drive components of a drive system:
1. Unintentional movements of driven machine components during commissioning,
operation, maintenance, and repairs caused by, for example,
Hardware and/or software errors in the sensors, control system, actuators, and cables
and connections
Response times of the control system and of the drive
Operation and/or environmental conditions outside the specification
Condensation/conductive contamination
Errors during the assembly, installation, programming and parameterization
Use of wireless devices/mobile phones in the immediate vicinity of the control system
External influences/damage
2. In case of failure, unusually high temperatures inside and outside the motor, including
open fire as well as the emission of light, noise, particles, gases, etc. can result, for
example in
Component failure
Software errors in converter operation
Operation and/or environmental conditions outside the specification
External influences/damage
3. Hazardous shock voltages caused by, for example,
Component failure
Influence during electrostatic charging
Induction of voltages in moving motors
Operation and/or environmental conditions outside the specification
Condensation/conductive contamination
External influences/damage
4. Electrical, magnetic and electromagnetic fields generated in operation that can pose a
risk to people with a pacemaker, implants or metal replacement joints, etc., if they are too
close
5. Release of noxious substances and emissions in the case of improper operation and/or
improper disposal of components

Other manuals for Siemens SIMOTICS M-1PH8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS M-1PH8 and is the answer not in the manual?

Siemens SIMOTICS M-1PH8 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTICS M-1PH8
CategoryEngine
LanguageEnglish

Related product manuals