5 Rotate the encoder shaft together with the coupling
element into a position so that the di󹪜erent widths
of the coupling element slide into the matching lugs of
the motor shaft .
6 Place the encoder on the motor so that the recess in the
encoder housing 󹪝ts onto the lugs at the motor
housing .
7 Tighten the two M4 󹪝xing screws that 󹪝x the encoder.
The maximum tightening torque is 3 Nm.
8 Remove the gap 󹪝llers and
Clean the surfaces to remove any residue.