Getting Started
34 A5E36037886-003, 04/2017
Mounting the drive
For V90 200 V variant, use two M5 screws to mount the FSA and FSB drives and four M5 screws to mount the FSC, and
FSD drives.
For V90 400 V variant, use two M5 screws to mount the FSAA drive and four M5 screws to mount the FSA, FSB, and FSC
drives.
The recommended tightening torque is 2.0 Nm.