Getting Started
96 A5E36037886-003, 04/2017
Select the VIBSUP on/off.
Position setpoint filter can be activated (p29035) for IPos control mode.
• 0: Disable
Filter is not activated.
• 1: Enable
p29041[0..
.1]
Torque scaling 0 [0] 100
• [0]: The scaling for the analog torque setpoint.
With this parameter, you can specify the torque setpoint corresponding to full analog input (10 V).
• [1]: The scaling for the analog torque limit.
With this parameter, you can specify the torque limit corresponding to full analog input (10 V).
You can select the internal parameters or the analog input as the source of the torque limit with the combi-
nation of the digital input signals TLIM1 and TLIM2.
p29042 Offset adjustment for
-0.5000 0.5000 0.0000 V Float IM T
Description: Offset adjustment for the analog input 2.
Fixed torque setpoint.
You can select the internal parameters or the analog input as the source of the torque setpoint by configuring
the digital input signal TSET.
p29045 PTI: activate travel to
0 1 0 - I16 IM T
Description: Activate/deactivate "travel to fixed stop" function under PTI control mode.
1: Travel to fixed stop is active
0: Travel to fixed stop is inactive
Positive torque limit.
Three internal torque limits in total are available.
You can select the internal parameters or the analog input as the source of the torque limit with the combina-
tion of the digital input signals TLIM1 and TLIM2.
Negative torque limit.
Three internal torque limits in total are available.
You can select the internal parameters or the analog input as the source of the torque limit with the combina-
tion of the digital input signals TLIM1 and TLIM2.
The scaling for the analog speed setpoint.
With this parameter, you can specify the speed setpoint corresponding to full analog input (10 V).