EasyManua.ls Logo

Siemens SINAMICS G120 - Interface to the Power Module (Pem, P0300 = 2 Xx)

Siemens SINAMICS G120
732 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Vector control
Function diagrams
2-599
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 01/2011
Fig. 2-90 6731 – Interface to the Power Module (PEM, p0300 = 2xx)
- 6731 -
Function diagram
87654321
FP_6731_97_51.vsd
Vector control
G120 CU230P-2
13.12.2010 V4.4
Interface to the Power Module (PEM, p0300 = 2xx)
PWM
M
~
+
U
V
W
+ BRP
-BRN
P24
M
p1795
2
I_max Power Module
[6640.1]
[6310.1]
[6799.1]
[6714.8]
[6714.8]
[6799.1]
[6799.1]
[6724.1]
[6799.1]
[6714.1]
r1751
p1764 p1767
++
r1771
+
+
r1770
[2526.2]
Precontrol speed
Brake control
I_max Power Module
Pulse enable HW
DC link voltage
Power Module
Control Unit
U_set
U_angle
Motor model
r1762, r1778
Model control
kT estimator
p0328
p0316
p0357
p1780.3
PEM: Permanent-magnet synchronous motor
r0070
Vdc act val [V]
r0072
U_output [Veff]
r0074
Modulat_depth [%]
ZSW cl-loop ctrl
r0056
r0056
.11
r0066
f_outp [Hz]
ZSW cl-loop ctrl
r0056
r0056
.7
MotMod kT corr [Nm/A]
r1797 [D]
r0094
Transformat_angle [°]
U_phase act val
r0089
PM-IF
r1733
Quad U set [Veff]
r0077
Iq_set [Aeff]
r0076
Id_act [Aeff]
R_stator act [Ohm]
r0395 [D]
From thermal motor model
Vibration damping
Sign
+ or -
Current model
[6030.8]
Gain res_damp
p1740
p1755 p1756
Outp_ph_seq rev
p1820
r0063
n_act [1/min]
[0]
r1732
Direct U set [Veff]
[0]
r0069[0..6]
I_phase act value [A]