Commissioning
4.2 Commissioning with BOP-2 operator panel
SINAMICS G120C, FSD ... FSF inverters
Compact Operating Instructions, 11/2016, FW V4.7 SP6, A5E39339884B AA
53
Directly select the parameter number
The BOP-2 offers the possibility of setting the parameter number digit by digit.
The parameter number is flashing in the BOP-2 display.
To select the parameter number directly, proceed as follows:
Press the OK button for longer than five seconds.
Change the parameter number digit-by-digit.
If you press the OK button then the BOP-2 jumps to the next digit.
If you have entered all of the digits of the parameter number, press
the OK button.
You have now entered the parameter number directly.
Entering the parameter value directly
The BOP-2 offers the option of setting the parameter value digit by digit.
The parameter value flashes in the BOP-2 display.
To select the parameter value directly, proceed as follows:
Press the OK button for longer than five seconds.
Change the parameter value digit-by-digit.
If you press the OK button then the BOP-2 jumps to the next digit.
If you have entered all of the digits of the parameter value, press the
OK button.
You have now entered the parameter value directly.
When cannot you change a parameter?
The inverter indicates why it currently does not permit a parameter to be changed:
Read parameters cannot
be adjusted
The parameter can only be adjusted
during quick commissioning.
A parameter can only be adjusted
when the motor is switched off
The operating state in which you can change a parameter is provided in the List Manual for
each parameter.