Commissioning
4.2 Commissioning with BOP-2 operator panel
SINAMICS G120C, FSD ... FSF inverters
76 Compact Operating Instructions, 11/2016, FW V4.7 SP6, A5E39339884B AA
No.
Description
p20172
PDF 0 run sequence
p20173 BI: PDF 1 input pulse I
p20174
PDF 1 pulse delay time [ms]
r20175 BO: PDF 1 output Q
p20176
PDF 1 runtime group → same as p20096
p20177
PDF 1 run sequence
p20178
BI: PST 0 inputs
[0]
Input pulse I
[1]
Reset input R
p20179
PST 0 pulse duration [ms]
r20180
BO: PST 0 output Q
p20181
PST 0 runtime group → same as p20096
p20182
PST 0 run sequence
p20183
BI: PST 1 inputs → same as p20178
p20184
PST 1 pulse duration [ms]
r20185
BO: PST 1 output Q
p20186
PST 1 runtime group → same as p20096
p20187
PST 1 run sequence
p20188
BI: RSR 0 inputs
[0]
Set S
[1]
Reset R
r20189
BO: RSR 0 output Q
r20190 BO: RSR 0 inverted output QN
p20191
RSR 0 runtime group → same as p20032
p20192
RSR 0 run sequence
p20193
BI: RSR 1 inputs → same as p20188
r20194
BO: RSR 1 output Q
r20195
BO: RSR 1 inverted output QN
p20196 RSR 1 runtime group → same as p20032
p20197
RSR 1 run sequence
p20198
BI: DFR 0 inputs
[0]
Trigger input I
[1]
D input D
[2]
Set S
[3]
Reset R
r20199
BO: DFR 0 output Q
r20200
BO: DFR 0 inverted output QN
p20201
DFR 0 runtime group → same as p20032
p20202
DFR 0 run sequence
p20203
BI: DFR 1 inputs → same as p20198
r20204
BO: DFR 1 output Q
r20205
BO: DFR 1 inverted output QN
p20206
DFR 1 runtime group → same as p20032
p20207
DFR 1 run sequence
p20208
BI: BSW 0 inputs
[0]
Input I0
[1]
Input I1
No.
Description
p20209
BI: BSW 0 switch position I
r20210 BO: BSW 0 output Q
p20211
BSW 0 runtime group → same as p20032
p20212 BSW 0 run sequence
p20213
BI: BSW 1 inputs → same as p20208
p20214
BI: BSW 1 switch position I
r20215
BO: BSW 1 output Q
p20216
BSW 1 runtime group → same as p20032
p20217
BSW 1 run sequence
p20218
CI: NSW 0 inputs
[0]
Input X0
[1]
Input X1
p20219
BI: NSW 0 switch position I
r20220
CO: NSW 0 output Y
p20221
NSW 0 runtime group → same as p20096
p20222
NSW 0 run sequence
p20223
CI: NSW 1 inputs → same as p20218
p20224
BI: NSW 1 switch position I
r20225
CO: NSW 1 output Y
p20226
NSW 1 runtime group → same as p20096
p20227
NSW 1 run sequence
p20228 CI: LIM 0 input X
p20229
LIM 0 upper limit value LU
p20230
LIM 0 lower limit value LL
r20231
CO: LIM 0 output Y
r20232
BO: LIM 0 input variable at the upper limit QU
r20233
BO: LIM 0 input variable at the lower limit QL
p20234 LIM 0 runtime group → same as p20096
p20235
LIM 0 run sequence
p20236
CI: LIM 1 input X
p20237
LIM 1 upper limit value LU
p20238
LIM 1 lower limit value LL
r20239
CO: LIM 1 output Y
r20240
BO: LIM 1 input variable at the upper limit QU
r20241
BO: LIM 1 input variable at the lower limit QL
p20242
LIM 1 runtime group → same as p20096
p20243
LIM 1 run sequence
p20244
CI: PT1 0 inputs
[0]
Input x
[1]
Setting value SV
p20245
BI: PT1 0 accept setting value S
p20246
PT1 0 smoothing time constant [ms]
r20247
CO: PT1 0 output Y
p20248
PT1 0 runtime group → same as p20096