Commissioning
4.2 Commissioning with BOP-2 operator panel
SINAMICS G120C, FSD ... FSF inverters
Compact Operating Instructions, 11/2016, FW V4.7 SP6, A5E39339884B AA
77
No.
Description
p20249
PT1 0 run sequence
p20250 CI: PT1 1 inputs → same as p20244
p20251
BI: PT1 1 accept setting value S
p20252 PT1 1 smoothing time constant [ms]
r20253
CO: PT1 1 output Y
p20254
PT1 1 runtime group → same as p20096
p20255
PT1 1 run sequence
p20256
CI: INT 0 inputs → same as p20244
p20257
INT 0 upper limit value LU
p20258
INT 0 lower limit value LL
p20259
INT 0 integrating time constant [ms]
p20260
BI: INT 0 accept setting value S
r20261
CO: INT 0 output Y
r20262
BO: INT 0 integrator at the upper limit QU
r20263
BO: INT 0 integrator at the lower limit QL
p20264
INT 0 runtime group → same as p20096
p20265
INT 0 run sequence
p20266
CI: LVM 0 input X
p20267
LVM 0 interval mean value M
p20268
LVM 0 interval limit L
p20269 LVM 0 hysteresis HY
r20270
BO: LVM 0 input variable above interval QU
r20271
BO: LVM 0 input variable within interval QM
r20272
BO: LVM 0 input variable below interval QL
p20273
LVM 0 runtime group → same as p20096
p20274
LVM 0 run sequence
p20275 CI: LVM 1 input X
p20276
LVM 1 interval mean value M
p20277
LVM 1 interval limit L
p20278
LVM 1 hysteresis HY
r20279
BO: LVM 1 input variable above interval QU
r20280
BO: LVM 1 input variable within interval QM
r20281
BO: LVM 1 input variable below interval QL
p20282
LVM 1 runtime group → same as p20096
p20283
LVM 1 run sequence
p20284
CI: DIF 0 input X
p20285
DIF 0 differential time constant [ms]
r20286
CO: DIF 0 output Y
p20287
DIF 0 runtime group → same as p20096
p20288
DIF 0 run sequence
p20300
BI: NOT 4 input I
r20301
BO: NOT 4 inverted output
No.
Description
p20302
NOT 4 runtime group → same as p20032
p20303 NOT 4 run sequence
p20304
BI: NOT 5 input I
r20305 BO: NOT 5 inverted output
p20306
NOT 5 runtime group → same as p20032
p20307
NOT 5 run sequence
p20308
CI: ADD 2 inputs → same as p20094
r20309
CO: ADD 2 output Y
p20310
ADD 2 runtime group → same as p20096
p20311
ADD 2 run sequence
p20312
CI: NCM 0 inputs
[0]
Input X0
[1]
Input X1
r20313
BO: NCM 0 output QU (QU = 1 if X0 > X1)
r20314
BO: NCM 0 output QE (QE = 1 if X0 = X1)
r20315
BO: NCM 0 output QL (QL = 1 if X0 < X1)
p20316
NCM 0 runtime group → same as p20096
p20317
NCM 0 run sequence
p20318
CI: NCM 1 inputs
[0]
Input X0
[1]
Input X1
r20319
BO: NCM 1 output QU (QU = 1 if X0 > X1)
r20320 BO: NCM 1 output QE (QE = 1 if X0 = X1)
r20321
BO: NCM 1 output QL (QL = 1 if X0 < X1)
p20322
NCM 1 runtime group → same as p20096
p20323
NCM 1 run sequence
p20324
BI: RSR 2 inputs
[0]
Set S
[1]
Reset R
r20325 BO: RSR 2 output Q
r20326
BO: RSR 2 inverted output QN
p20327
RSR 2 runtime group → same as p20032
p20328
RSR 2 run sequence
p20329
BI: DFR 2 inputs → same as p20198
r20330
BO: DFR 2 output Q
r20331
BO: DFR 2 inverted output QN
p20332
DFR 2 runtime group → same as p20032
p20333
DFR 2 run sequence
p20334
BI: PDE 2 input pulse I
p20335
PDE 2 pulse delay time [ms]
r20336
BO: PDE 2 output Q
p20337
PDE 2 runtime group → same as p20096
p20338
PDE 2 run sequence
p20339
BI: PDE 3 input pulse I
p20340
PDE 3 pulse delay time [ms]