Installing
3.5 Default setting of the interfaces
CU230P-2 Control Units
Compact Operating Instructions, 01/2017, A5E38815802B AA
19
Default setting 15: "Process industry"
DO 0: p0730,
DO 1: p0731
AO 0: p0771[0],
AO 1: p0771[1]
DI 0: r0722.0, …, DI 5: r0722.5 AI 0: r0755[0]
Motorized potentiometer, setpoint after the ramp-function generator: r1050
Speed setpoint (main setpoint): p1070[0] = 755[0], p1070[1] = 1050
Designation in the BOP-2: Proc
Default setting 17: "2-wire (forward/backward 1)"
DO 0: p0730,
DO 1: p0731
AO 0: p0771[0],
AO 1: p0771[1]
DI 0: r0722.0, …, DI 2: r0722.2 AI 0: r0755[0]
Speed setpoint (main setpoint): p1070[0] = 755[0]
Designation in the BOP-2: 2-wIrE 1