EasyManua.ls Logo

Siemens SINAMICS IOP-2 - Page 31

Siemens SINAMICS IOP-2
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Setup Menu
6.1 Example Setups
Intelligent Operating Panel 2 (IOP-2)
Operating Instructions, 06/2020, FW V2.6, A5E39549448B AH
29
Advanced Startup
The Advanced Startup provides the user with a more comprehensive range of settings that
can be configured for specific requirements and applications. The settings that are available
are as follows:
Drive Information: This displayed detailed information about the connected Control Unit
and Power Module.
Factory Reset: This allows the converter to be reset to the factory default settings.
Hardware options: This allows the configuring of and Output Filter and a Braking Resistor.
Control Type: This allows the selection of the control types, Standard Drive Control,
Dynamics Drive Control and Expert. A brief explanation of each Control Type is given
below.
Motor Data: This allows the user to configure the Motor settings which consist of the data
presented in the Quick Setup.
Limit Settings: This gives the user the opportunity to setup the dynamics settings of the
converter.
Optimization: This allows the user to optimize the converter for technological applications
and ensure that the correct motor data will be used.
I/O Setup: This allows the user to configure the Input and Output settings of the converter.
The I/O configuration is pre-assigned using macros so that no further settings are
necessary.
Fieldbus Setup: This allows the user to configure the interface settings.
Application Setup: This allows the user to configure the application specific functions of
the converter.
For more detailed information of the application classes, see the document at the link below:
Application classes (https://support.industry.siemens.com/cs/ww/en/view/109480663
)
Control Types
Standard Drive Control
Standard Drive Control is preset for the Power Modules PM240, PM240-2 and G120C in
frame sizes FSA-C. This application class can, for example, be used for the following
applications:
Pumps, fans and compressors with flow characteristic
Wet or dry beam technology, mills, mixers, kneaders, crushers, agitators
Horizontal conveyor technology (conveyor belts, roller conveyors, chain conveyors)
Basic spindles

Related product manuals