9.1 Door mounting kit
Intelligent Operating Panel 2 (IOP-2)
72 Operating Instructions, 06/2020, FW V2.6, A5E39549448B AH
Figure 9-2 Fitting Operator Panel DMK (thread-forming screws)
CAUTION
Thread-forming screws maximum torques
Using a torque greater than 1.2 Nm with the thread-forming screws may lead to permanent
damage of the threads. The thread-forming screws must be correctly aligned with the holes
on the back of the OP; the thread-forming screws must not be used with the OPs with the
brass inserts.
Prior to the installation of the DMK, it is necessary to create a hole in the panel or cabinet
with the dimensions as shown in the figure below: