4. Use cable ties to secure the cable at appropriate locations.
5. Feed
the cable up through the cabinet and, at the height of the Control Unit, route it directly
up and to the right towards the Control Unit. Route the cable corresponding to the standard
cable prerouted in the cabinet.
6. Use cable ties to secure the cable at appropriate locations.
7. Connect the cable to the Control Unit.
Information regarding connecting the cable is provided in the "Control cabinets and
supplementary system components" manual.
5.4.5.3 Cable routing for DRIVE-CLiQ connections and signal cables
1. Route the DRIVE-CLiQ/signal cable from the bottom left in the cabinet.
2. Use cable ties to secure the cable at appropriate locations.
3. Feed the cable up through the cabinet and, at the height of the Control Unit, route it directly
up and to the right towards the Control Unit. Route the cable corresponding to the standard
cable prerouted in the cabinet.
4. Use cable ties to secure the cable at appropriate locations.
5. Connect the DRIVE-CLiQ/signal cable to the Control Unit.
Electrical connection
5.4 Cable routing
Applications for Cabinet Modules, liquid cooled
92 Operating Instructions, 04/2015, A5E35974555A