4.2 Design
Components
The following components are required for the parallel connection:
●
1 SINAMICS Control Unit CU320-2
●
2 SINAMICS S120 Motor Modules Booksize
●
Line Modules, e.g. SINAMICS S120 Active Line Modules
● SINAMICS S120 Sensor Module SMC30 (optional)
● Asynchronous motor
● SINAMICS motor reactors (optional)
– 6SE7031-8ES87-1FE0 (for Motor Module 132 A)
– 6SE7032-6ES87-1FE0 (for Motor Module 200 A)
Hardware
4.2 Design
Motor Modules Booksize parallel connection
Application Manual, 01/2020, 6SL3097-5BF00-0BP0 27