Data Display Menu
Status
Parameter Set
Function
Data Display
M
M
M
M
M
ENTER
ENTER
ENTER
M
or
D10 value
Data No. 11
Data No. 81
Data No. 82
Data No. 10
The default menu item
under current menu level
Actual menu display
Figure 6-4 "Data Display" menu
N
ote
Detailed description of individual display data can be found in Section 6.5 "Display data list
(Page 49)".
31400
31020
STEP_RESOL
ENC_RESOL PPR
IPR
X, Z (for 801)
X, Y, Z (for 802S base line)
X, Z (for 801)
X, Y, Z (for 802S base line)
10,000
10,000
Encoder revolution (2,500)
x Multiplier (4)
Steps per servo motor revolution
noitpircseDtniopteSnoitangiseDataD enihcaM Unit Axis
3.1.3 Setpoints from NC
EN-22 SINAMICS V60 Controlled Power Module (CPM60.1) Getting Started