2. Installation
2.5 Device identification
Sensor MASS 2100 label
Signal converter
MASS 6000 19" IP 20 and
IP 65 label
No. Meaning
1. Notified body for QA supervision: UL International DEMKO A/S, Denmark
2. Explosion protected
3. ATEX Equipment Group and Protection Category
4. Maximum medium temperature
5. EC Approval Numbers and Protection Type
6. Production year
7. Build-up code, "1" = MASS 2100 sensor
8. PED = Pressure Equipment Directive 97/23/EC
PED: SEP marking indicating that the sensor is produced in accordance with
"Sound Engineering Practice"
CE 0200 EN 13480 - category II marking indicating that the sensor conforms to PED-
category II
9. Ambient temperature range
10. Interface data
11. DN = sensor size
PN = max. pressure
PT = test pressure, sensor pressure tested with 1.5 x PN