5
!
Remote installation
Getrennte Montage
-
Montage séparé
.
Instalación remota
Ø PN 10 PN 16 PN 40 Class 150
mm inch Nm f/lbs Nm f/lbs Nm f/lbs Nm f/lbs
25 1” N/A N/A N/A N/A 10 7 7 5
40 1½” N/A N/A N/A N/A 16 12 9 7
50 2” N/A N/A 25 18 N/A N/A 25 18
65 2½ N/A N/A 25 18 N/A N/A 25 18
80 3 N/A N/A 25 18 N/A N/A 34 25
100 4 N/A N/A 25 18 N/A N/A 26 19
125 5 N/A N/A 29 21 N/A N/A 42 31
150 6 N/A N/A 50 37 N/A N/A 57 42
200 8 50 37 50 37 N/A N/A 88 65
250 10 50 37 82 61 N/A N/A 99 73
300 12 57 42 111 82 N/A N/A 132 97
350 14 60 44 120 89 N/A N/A 225 166
400 16 88 65 170 125 N/A N/A 210 155
450 18 92 68 170 125 N/A N/A 220 162
500 20 103 76 230 170 N/A N/A 200 148
600 24 161 119 350 258 N/A N/A 280 207
!
Maximum allowable
torques
Maximal zulässige
Dreh-momente
-
Couples maximum
autorisés
.
Pares máximos
!
Installation
-
Installation
Installation
.
Instalación