Type | Electromagnetic Flowmeter |
---|---|
Measurement Principle | Electromagnetic |
Nominal Diameter | DN 25 to DN 1200 |
Temperature Range (Ambient) | -20 to +60 °C |
Output Signal | 4 to 20 mA |
Power Supply | 24 V DC |
Protection Degree | IP 68 |
Lining Material | PTFE |
Electrode Material | Stainless steel |
Material | Stainless steel |
Approvals | ATEX, IECEx |
Important safety and operational instructions for using the equipment and software.
Details on product design, safety, and battery handling precautions.
Guidelines for physical mounting, flow direction, and pipe conditions.
Procedures for grounding the sensor body for electrical noise and lightning protection.
Specifies torque values for bolts to ensure proper installation and prevent leakage.
Details on connecting the meter to power and communication interfaces like RS232 and RS485.
Procedures to maintain the meter's IP68/NEMA 6P enclosure rating, especially when using cable glands.
Steps to establish communication between a PC and the meter using IrDA interface.
Information on the password protection feature for meter data and configuration.
Basic configuration for selecting volume and flow rate units.
Configuration options for pulse outputs, including volume, alarm, and call-up functions.
Details of meter parameters, their FT IDs, factory settings, and data ranges.
How to navigate the meter's display and operate it using the single interface key.
Explains the different indices available in the operator menu and their functions.
Details on battery management, capacity, and influencing factors.
Step-by-step guide for replacing the internal battery pack and ensuring proper sealing.
Notes on user sealing for MAG 8000 CT verification.
General guidelines for meter service, troubleshooting, and problem detection.
Lists and explains various fault codes, their descriptions, and alarm reasons.
Guidance on replacing the transmitter or PCB board, including different replacement options.
Comprehensive technical specifications for the meter, including accuracy, temperature, and approvals.
Details on meter accuracy, calibration standards, and uncertainty specifications.
Diagrams and tables detailing the physical dimensions and flange specifications of the meter.
List of available accessories for the meter, including order numbers and symbols.
List of spare parts available for the transmitter, PCB, and cables, with order numbers.