DEVICE DESCRIPTION
8
SITRANS FX330
www.siemens.com/flow 09/2018 - A5E40861058-AB
2.5 Types of protection
The following types of protection are used:
The following types of protection are used:The following types of protection are used:
The following types of protection are used:
Electronics compartment Ex db (Gb) or Ex tb (Db)
Ex db (Gb) or Ex tb (Db)Ex db (Gb) or Ex tb (Db)
Ex db (Gb) or Ex tb (Db)
Terminal compartment either Ex db or Ex eb (Gb) or Ex tb (Db)
either Ex db or Ex eb (Gb) or Ex tb (Db)either Ex db or Ex eb (Gb) or Ex tb (Db)
either Ex db or Ex eb (Gb) or Ex tb (Db)
Flow sensor Ex ia (Gb or Db)
Ex ia (Gb or Db)Ex ia (Gb or Db)
Ex ia (Gb or Db)
Marking for the flameproof version of compact versions:
Marking for the flameproof version of compact versions:Marking for the flameproof version of compact versions:
Marking for the flameproof version of compact versions:
ATEX II 2 G
II 2 GII 2 G
II 2 G Ex db ia IIC T6...T2 Gb
Ex db ia IIC T6...T2 GbEx db ia IIC T6...T2 Gb
Ex db ia IIC T6...T2 Gb
or
Ex db eb ia IIC T6...T2 Gb
Ex db eb ia IIC T6...T2 GbEx db eb ia IIC T6...T2 Gb
Ex db eb ia IIC T6...T2 Gb
IECEx Ex db ia IIC T6...T2 Gb
Ex db ia IIC T6...T2 GbEx db ia IIC T6...T2 Gb
Ex db ia IIC T6...T2 Gb
or
Ex db eb ia IIC T6...T2 Gb
Ex db eb ia IIC T6...T2 GbEx db eb ia IIC T6...T2 Gb
Ex db eb ia IIC T6...T2 Gb
Marking for the flameproof version of remote versions:
Marking for the flameproof version of remote versions:Marking for the flameproof version of remote versions:
Marking for the flameproof version of remote versions:
ATEX II 2 G
II 2 GII 2 G
II 2 G Ex db [ia] IIC T6 Gb
Ex db [ia] IIC T6 GbEx db [ia] IIC T6 Gb
Ex db [ia] IIC T6 Gb (signal converter)
or
Ex db eb [ia] IIC T6 Gb
Ex db eb [ia] IIC T6 GbEx db eb [ia] IIC T6 Gb
Ex db eb [ia] IIC T6 Gb
II 2 G
II 2 GII 2 G
II 2 G Ex ia IIC T6...T2 Gb
Ex ia IIC T6...T2 GbEx ia IIC T6...T2 Gb
Ex ia IIC T6...T2 Gb (flow sensor)
IECEx Ex db [ia] IIC T6 Gb
Ex db [ia] IIC T6 GbEx db [ia] IIC T6 Gb
Ex db [ia] IIC T6 Gb (signal converter)
or
Ex db eb [ia] IIC T6 Gb
Ex db eb [ia] IIC T6 GbEx db eb [ia] IIC T6 Gb
Ex db eb [ia] IIC T6 Gb
Ex ia IIC T6...T2 Gb
Ex ia IIC T6...T2 GbEx ia IIC T6...T2 Gb
Ex ia IIC T6...T2 Gb (flow sensor)
Marking for the dustproof version of compact versions:
Marking for the dustproof version of compact versions:Marking for the dustproof version of compact versions:
Marking for the dustproof version of compact versions:
ATEX II 2 D
II 2 DII 2 D
II 2 D Ex tb ia IIIC T70
Ex tb ia IIIC T70Ex tb ia IIIC T70
Ex tb ia IIIC T70°C...T240
C...T240C...T240
C...T240°C Db
C DbC Db
C Db
IECEx Ex tb ia IIIC T70
Ex tb ia IIIC T70Ex tb ia IIIC T70
Ex tb ia IIIC T70°C...T240
C...T240C...T240
C...T240°C Db
C DbC Db
C Db
Marking for the dustproof version of remote versions:
Marking for the dustproof version of remote versions:Marking for the dustproof version of remote versions:
Marking for the dustproof version of remote versions:
ATEX II 2 D
II 2 DII 2 D
II 2 D Ex tb [ia] IIIC T70
Ex tb [ia] IIIC T70Ex tb [ia] IIIC T70
Ex tb [ia] IIIC T70°C Db
C DbC Db
C Db (signal converter)
II 2 D
II 2 DII 2 D
II 2 D Ex ia IIIC T70
Ex ia IIIC T70Ex ia IIIC T70
Ex ia IIIC T70°C...T240
C...T240C...T240
C...T240°C Db
C DbC Db
C Db (flow sensor)
IECEx Ex tb [ia] IIIC T70
Ex tb [ia] IIIC T70Ex tb [ia] IIIC T70
Ex tb [ia] IIIC T70°C Db
C DbC Db
C Db (signal converter)
Ex ia IIIC T70
Ex ia IIIC T70Ex ia IIIC T70
Ex ia IIIC T70°C...T240
C...T240C...T240
C...T240°C Db
C DbC Db
C Db (flow sensor)

Other manuals for Siemens Sitrans F Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Sitrans F Series and is the answer not in the manual?

Siemens Sitrans F Series Specifications

General IconGeneral
Measurement PrincipleCoriolis, Electromagnetic, Ultrasonic
Communication ProtocolsHART, PROFIBUS, Foundation Fieldbus, Modbus
Pressure RangeVaries by model (e.g., up to 400 bar for some models)
Power Supply24 V DC or 110-230 V AC
Protection ClassIP67, IP68
Housing MaterialStainless steel, aluminum
Liner MaterialPTFE, PFA, rubber
Electrode MaterialStainless steel, Hastelloy, platinum