A5E32106153 SITRANS Probe LR – MANUAL FÖR SNABBSTART Sida SV-3
mmmmm
Svenska
Effekt
Maximum 30 V DC
4 till 20 mA
Godkännanden
Allmänt: CSA
US/C
, FM, CE, C-TICK
Radio: Europa (R&TTE), FCC, Industry Canada
Riskfylld Fullständigt
antändningssäker (Europa) ATEX II 1 G EEx ia IIC T4
(USA/Kanada) FM/CSA
1
: (barriär erforderlig)
Klass I, Div. 1, Grupperna A, B, C, D
Klass II, Div. 1, Grupperna E, F, G
Klass III T4
(Australien) ANZEx Ex ia IIC T4
(Tomg = -40 till + 80 °C) IP67, IP68
(Internationell) IECEx TSA 04.0020X Ex ia IIC T4
(Brazil) INMETRO: DNV 12.0068 X
Ex ia IIC T4 Ga
IP66/IP67/IP68
-40 ºC
T a +80 ºC
DNV #OCP 0017
ABNT NBR IEC 60079-0:2008 e
ABNT NBR IEC 60079-11:2009
Icke-antändlig (US) FM
2
:
Klass I, Div. 2, Grupperna A, B, C, DT5
Marin Lloyds Skeppningsregister
ABS Typgodkännande
Mekanik
Processanslutningar:
gängad anslutning 1,5" NPT, BSP, eller G (BS EN ISO 228-1)
•Antenn:
polypropylenstång Hermetiskt tillsluten konstruktion
Nominell 24 V likström vid max. 550 Ohm:
1.
Se “Wiring Drawing: Intrinsically Safe (FM )” på sida 2 i bilaga A, för ritningsnummer 23651611, eller
“Wiring Drawing: Intrinsically Safe (CSA)” på sida 3 i bilaga A, för ritningsnummer 23651621.
2.
Se “Wiring Drawing: Non-incendive (FM)” på sida 1 i bilaga A, för ritningsnummer 23650537.
Anmärkning: Användning av godkända vattentäta ledningsnav/packboxar erfordras för
Typ 4X / NEMA 4X, Typ 6 / NEMA 6, IP67 (utomhus tillämpningar).
Anmärkning: Provning EN61000-4-3 (CE EMC) utfördes på SITRANS Probe LR när den var
monterad i ett plåtkärl.